CATEGORIAS
Test nitrogen gas dew point if can be reach -40℃
Judgment Standard: Qualified if atmospheric pressure dew point ≤ -40℃
The dew point of nitrogen indicates the water vapor content in nitrogen: the lower the dew point temperature, the less moisture there is. A dew point of -40°C is the general industrial threshold for dry nitrogen. Excessive moisture will directly lead to product scrapping, equipment damage, process failures and potential safety hazards.
Sep 9th,2026
9 Visualizações
Use Portable Capacitance Dew Point Meter (For On-site Rapid Inspection)
Handheld and portable, with a measuring range of -70 to +20°C and an accuracy of ±1 to ±2°C, suitable for quick on-site judgment. If the reading falls within the range of -38 to -42°C, it can be approximately regarded as meeting the -40 grade standard.
Why does the industry commonly target a dew point of -40°C?
At atmospheric pressure, a dew point of -40°C corresponds to a water vapor content of approximately 124 ppm, marking the cost-performance balance point:
Above -40°C (e.g., -30°C, -35°C): Excess moisture leads to oxidation and defects in most precision processes;
≤ -40°C: Meets basic moisture and oxidation prevention requirements for the vast majority of welding, electronics, heat treatment and packaging processes;